    Apresentação de plano de manutenção, operação e controle desenvolvido para aplicação no sistema de ar-condicionado do edifício sede da TV universitária da Universidade Federal do Amazonas
    (2017-06-26) Pessoa, Marcelo Girão; Machado, Carlos José Baptista; http://lattes.cnpq.br/2613703649034215; Machado, Carlos José Baptista; http://lattes.cnpq.br/2613703649034215; Rodrigues Filho, João Nery; http://lattes.cnpq.br/3860803328978892; Santos, Antônio Aurélio Pereira dos; http://lattes.cnpq.br/4252052970703374
    Throughout its history, the air conditioner has evolved and consolidated as an indispensable machine for the population, for providing its well-being, this one directly related to thermal comfort, and also for the achievement of the various productivity goals of companies or institutions . However, because it is a machine that treats the air in a closed environment, if it is not properly maintained, it can negatively affect the users' health, causing illnesses or worsening the clinical condition of people with preexisting diseases and even taking To death. To avoid such problems, the Ministerial Order No. 3,523/98 was regulated by the Ministry of Health, which establishes rules and procedures to be practiced in collective settings. The city of Manaus has a hot and humid climate, where the use of air conditioning is undoubtedly necessary, so the UFAM TV building located in the urban area of the city requires air conditioning machines for its operation. This study seeks to present the PMOC required to the system of air conditioning of such a building so that it meets the current legislation. For this, an inventory of the air conditioning machines installed in the building was carried out to obtain information relevant to the installed project. Visual inspections were performed at the facility to detect possible problems. Finally, as a result, the PMOC was presented and could be implemented, in accordance with current regulations. Therefore, the entire development process was salutary for understanding, as well as for the proposal of the resulting Maintenance, Operation and Control Plan.